Dose calculation in opioid rotation: electronic calculator vs. manual calculation
Herbert Plagge1, Wilhelm Ruppen, Norman Ott
1Hospital Pharmacy, University Hospital Basel, Basel, Switzerland. hplagge@uhbs.ch
Objective:
To generate, validate and establish a web-based individualised opioid conversion calculator at the University Hospital Basel and to analyse its value and significance.
Setting:
A 700-bed university hospital.
Method:
Published data were screened by a Medline search using the keywords: opioid, rotation, switching, potency and dose ratio. Based on this data, the criteria for the conversion calculator were defined. A prospective process validation was performed prior to the approval. Five months after the introduction of the tool, an online survey was performed in order to evaluate its acceptance by users. In the last step, a manual calculation using a written table was compared with the calculator in a cross-over trial with 72 participants in order to assess the findings of the survey.
Results:
The opioid conversion calculator could be generated for 24 combinations of 6 opioids for 5 different routes of administration. The validation of the calculator was performed successfully without discovering any major or critical defects. The proportion of correct answers increased from 68% using the table to 81% using the calculator (P < 0.001), the median time necessary to answer the ten questions was 8.9 min using the table and 4.8 min using the calculator.
Conclusion:
A web-based opioid conversion calculator was planned, generated, validated and established at the hospital. Based on the results of the online survey and the results of our cross-over trial we conclude that the tool saves time compared to manual calculation and may contribute to patient safety by avoiding calculation errors. With this tool we contribute to the optimisation of processes in hospital and patient safety.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
IV Infusion to Oral Dosing: Conversion Methods
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Dosage Regimen Designs: Nomograms and Tabulations
Dosage Regimens: Designs and Approaches