High-order nonlinear Schrödinger equation and weak-light superluminal solitons in active Raman gain media with two

Chengjie Zhu1, Guoxiang Huang

  • 1Department of Physics, East China Normal University, Shanghai 200062, China.

Optics Express
|March 4, 2011
PubMed

Related Concept Videos

Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Standing Waves in a Cavity01:28

Standing Waves in a Cavity

A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...