Application of wet effluent diffusion denuder for measurement of uptake coefficient of gaseous pollutants
Kamil Motyka1, Pavel Mikuška, Zbyněk Večeřa
1Department of Organic Chemistry, Faculty of Science, Institute of Molecular and Translational Medicine, Palacký University, 17. listopadu 12, 771 46 Olomouc, Czech Republic. motyka@orgchem.upol.cz
Abstract:
The comparison of theoretical approaches describing the collection of analyte in the cylindrical wet effluent diffusion denuder (CWEDD) with experimental data is presented. Various absorption liquids were tested for the collection of formaldehyde (distilled-deionized water, H(2)SO(4) solution), acetaldehyde (distilled-deionized water) and nitrous acid (distilled-deionized water, sodium carbonate and sodium bicarbonate solutions of various concentrations and sodium phosphate pH 6-8) in CWEDD. pH of absorption liquids significantly influences the collection of formaldehyde as well as nitrous acid. The collection efficiency of formaldehyde for 0.05 M H(2)SO(4) as absorption liquid was generally higher than for distilled-deionized water. Absorption liquid pH markedly affected the collection efficiency of HONO too (with increasing pH the collection efficiency increase). Data derived by Gormley-Kennedy equation for all investigated compounds were overestimated especially for higher flow rates of air, data calculated with respect to Henry constant are not in good agreement with experimental data and are considerably depended on a determination of the Henry constant value. The CWEDD can be alternative tool for the determination of uptake coefficient. Obtained uptake coefficients were in good agreement with data found in other literature.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...