Related Experiment Video
Updated: Jun 3, 2026

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Highly sensitive electrochemical label-free aptasensor based on dual electrocatalytic amplification of Pt-AuNPs and
Lijuan Bai1, Ruo Yuan, Yaqin Chai
1Education Ministry Key Laboratory on Luminescence and Real-Time Analysis, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, People's Republic of China.
Abstract:
In this work, a label-free electrochemical aptamer-based sensor (aptasensor) was constructed on account of the direct immobilization of redox probes on an electrode surface. For this proposed aptasensor, a gold nanoparticles (AuNPs)-coated electrode was firstly modified with redox probes-nickel hexacyanoferrates nanoparticles (NiHCFNPs) through chemisorption and electrostatic adsorption. Then, platinum-gold alloy nanoparticles (Pt-AuNPs) and horseradish peroxidase (HRP) were respectively assembled onto the modified electrode surface, which formed the multilayer films for amplifying the electrochemical signal of NiHCFNPs and immobilizing thiolated thrombin aptamers (TBAs). In the presence of target thrombin, the TBA on the multilayer could catch the thrombin onto the electrode surface, which resulted in a barrier for electro-transfer, leading to the decrease of the electrochemical signal of NiHCFNPs amplified by the Pt-AuNPs and HRP toward H(2)O(2). The proposed method avoided the redox probes labeling process, increased the amount of redox probes, and further amplified the electrochemical signal. Thus, the approach showed a high sensitivity and a wider linearity to thrombin in the range between 0.01 nM and 50 nM with a detection limit of 6.3 pM.