Related Experiment Video
Updated: Jun 3, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Changes in pulse pressure following fluid loading: a comparison between aortic root (non-invasive tonometry) and
Nicolas Dufour1, Denis Chemla, Jean-Louis Teboul
1Service de Réanimation Médicale, Hôpital Bicêtre, Assistance Publique, Hôpitaux de Paris, Université Paris Sud 11, 78, rue du Général Leclerc, 94270 Le Kremlin-Bicêtre, France.
Purpose:
To document the relationship between stroke volume (SV) and pulse pressure (PP) recorded at the femoral and aortic sites during volume expansion (VE) in patients in shock. We hypothesized that non-invasively estimated aortic PP would exhibit the same ability as PP recorded invasively at the femoral level to track SV changes.
Methods:
Included in this prospective study were 56 ICU patients needing VE. Femoral PP (indwelling catheter), aortic PP (tonometry) and cardiac output (thermodilution) were recorded before and after VE. Responders were defined as patients who showed an increase in SV of ≥15% after VE.
Results:
Of the 56 included patients in shock, 39 (age 57 ± 14 years, SAPS II 46 ± 18) completed the study. At both sites, PP increased after VE in responders (n=17, mean SV increase 30 ± 15%) but not in non-responders. In the overall population, there was a positive relationship between VE-induced changes in SV and in PP at the femoral (r=0.60, p<0.001) and aortic (r=0.52, p<0.001) sites. Increases in femoral PP of ≥9% indicated SV increases of ≥15% with 82% sensitivity and 95% specificity. Increases in aortic PP of ≥4.5% indicated SV increases of ≥15% with 76% sensitivity and 82% specificity. Areas under the ROC curves indicated that aortic PP was not different from femoral PP for tracking changes in SV.
Conclusion:
The ability of non-invasively estimated aortic PP to track fluid response was the same as that of invasively recorded femoral PP. This may have implications for non-invasive haemodynamic monitoring.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical indicator...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure