Related Experiment Video
Updated: Jun 3, 2026

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Mid-infrared laser spectroscopy for online analysis of exhaled CO
Marcus Sowa1, Manfred Mürtz, Peter Hering
1Institut für Lasermedizin, Heinrich-Heine-Universität, Universitätsstr. 1, 40225 Düsseldorf, Germany. marcus.sowa@uni-duesseldorf.de
Abstract:
Carbon monoxide (CO) detection in human breath is the focus of much research because of CO's possible use as a marker molecule for different diseases. Detecting CO in human breath remains a tough challenge because of the low concentrations of CO (ppm range) that must be detected. Another problem is that many other molecules, which can be found in human breath, can interfere in these measurements. Additionally, a time resolution of less than 1 s is needed to resolve the CO curve of an exhalation. In this study (13)CO instead of (12)CO concentration is measured. The measurements are performed with a cavity leak-out spectroscopy system. The system's properties match the above-mentioned specifications for measurements, even of the rare isotopologue with high specificity, a time resolution of less than 1 s and a detection limit of 7 ppb Hz(-1/2). Two investigations are presented here. The first is a measurement showing intraday changes between 9.5% and 23.3% of the exhaled CO level due to vigorous exercise. The second shows a long-term observation of the CO base level revealing natural variations in the recorded CO concentration. The covered time period is 25 weeks during which the differences between the minimum and maximum CO levels for each test case reached 84%.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
IR Spectrometers