Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
[Reliability in detection of tracheal intubation using cricoid palpation method]
Maiko Ishigaki1, Shinji Takahashi, Makoto Tanaka
1Department of Anesthesia, Tsukuba University Hospital, Tsukuba 305-0005.
Cricoid palpation methods (CPM) are unreliable for confirming tracheal intubation, with low specificity for esophageal intubation. Relying on CPM alone is not recommended; multiple confirmation methods are essential for patient safety.
Area of Science:
- Anesthesiology
- Patient Safety
- Airway Management
Context:
- Unrecognized esophageal intubation is a major cause of anesthetic complications.
- Existing methods for confirming tracheal tube placement are often unreliable.
- Cricoid palpation offers a potential method for detecting esophageal intubation.
Purpose:
- To evaluate the reliability of cricoid palpation methods (CPM) in detecting tracheal versus esophageal intubation.
- To assess the sensitivity and specificity of CPM for confirming endotracheal tube placement.
Summary:
- This study assessed CPM in 312 patients undergoing tracheal intubation.
- CPM demonstrated 88% sensitivity but only 42% specificity for esophageal intubation.
- Positive and negative predictive values were 95% and 23%, respectively; higher BMI reduced sensitivity.
Impact:
- CPM alone is insufficient for accurate tracheal tube placement confirmation.
- The findings underscore the need for using multiple methods to ensure correct tube placement.
- This research informs clinical practice to improve patient safety during anesthesia.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...