Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Investigation of a demand-controlled rebreather in connection with a diving accident
Oskar Frånberg1, Mikael Ericsson, Agneta Larsson
1Department of Environmental Physiology, School of Technology and Health, Royal Institute of Technology, Stockholm, Sweden. oskar.franberg@sth.kth.se
Abstract:
This paper describes the examination of a Halcyon RB80 semi-closed underwater breathing apparatus used in a diving accident in 2007. The apparatus was supplied with trimix (oxygen, nitrogen and helium) containing 31% oxygen. The duration of the dive was 105 minutes at 28 meters' average depth in fresh water, with a 19-minute oxygen decompression stop at 6 meters. Upon surfacing the diver experienced seizures and signs of severe neurological deficits. The apparatus was tested with regard to the oxygen fraction drop from the supply gas to the breathing loop--i.e., the oxygen fraction inhaled by the diver (FiO2) was investigated. The FiO2 was measured and found to be lower than the value stated on the manufacturer's web page at the time of the accident. This investigation suggests that during the dive, the actual FiO2% was 17.9-25.3%, which is considerably lower than the FiO2% used for decompression calculations (30%). The underestimation of FiO2 resulted in too short and/or too few decompression stops during ascent. The low FiO2 would also put a diver at risk of hypoxia at shallow depths. It is concluded that inadequate information on the performance of the rebreather was a major contributing factor to this accident.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Acute Respiratory Failure-III
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...