Related Experiment Video
Updated: Jun 3, 2026

Spatial Separation of Molecular Conformers and Clusters
Published on: January 9, 2014
Enhancing the configurational sampling of ions in aqueous solution using adiabatic decoupling with translational
Anna-Pitschna E Kunz1, Wilfred F van Gunsteren
1Laboratory of Physical Chemistry, Swiss Federal Institute of Technology ETH, Zürich, Switzerland.
Abstract:
Three methods to enhance the configurational sampling of ions in aqueous solution, temperature and Hamiltonian replica exchange and adiabatic decoupling with translational temperature scaling, were compared for a system of CaSO(4) in water. It took 11 replicas in the case of temperature replica exchange to make use of a diffusion coefficient that is a factor of 1.5 larger at 350 K compared to that at 300 K. Thirty replicas were required in the Hamiltonian replica exchange with charge reduction to reach uncharged ions that have a diffusion coefficient that is 2-7 times larger than the fully charged ones. The adiabatic decoupling technique with translational temperature scaling yielded a diffusion coefficient that was 15 times larger while keeping the distribution of the water molecules around the ions unaltered with respect to the standard temperature simulation. This result illustrates the efficiency of the adiabatic decoupling technique to enhance configurational sampling.
More Related Videos
10:52Multiscale Sampling of a Heterogeneous Water/Metal Catalyst Interface using Density Functional Theory and Force-Field Molecular Dynamics
Published on: April 12, 2019
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Phase Transitions: Melting and Freezing
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Dialysis