Validation of new image-derived arterial input functions at the aorta using 18F-fluoride positron emission tomography
Tanuj Puri1, Glen M Blake, Musib Siddique
1School of Medicine and Medical Sciences, University College Dublin, Ireland. tanuj.puri@ucd.ie
Objectives:
(i) To validate two new image-based methods for finding the plasma arterial input function (AIF) and evaluate the performance of these and two similar techniques against arterial sampling. (ii) To evaluate the performance of all four image-derived AIF (IDAIF) methods against arterial sampling for measuring the F plasma clearance (Ki) to the lumbar spine.
Methods:
Eight healthy postmenopausal women had a F-fluoride positron emission tomography scan of the lumbar spine. Venous blood samples were used to estimate the IDAIFs from: (i) a fixed population-based partial volume correction (PVC) factor method, (ii) a variable PVC factor method, (iii) the Chen method, and (iv) the Cook-Lodge method. Continuous arterial sampling and the respective Ki values were used as the gold standard against which the performance of the IDAIF methods was compared.
Results:
The IDAIFs were compared with direct arterial sampling in terms of the area under the curve values. The percentage root mean square error in area under the curves compared with arterial sampling were: (i) fixed PVC: 12.7%, (ii) variable PVC: 12.0%, (iii) Chen: 39.0%, and (iv) Cook-Lodge: 17.3%. There were small but significant differences in the Ki values found by all four methods compared with arterial sampling. Bland-Altman plots of Ki values showed the best agreement for the variable and fixed PVC methods with a standard deviation of 0.0026 and 0.0030 ml/min/ml, respectively.
Conclusion:
The differences in the Ki values obtained at the lumbar spine using direct arterial sampling and any of the IDAIF methods at the aorta were clinically nonsignificant. The variable PVC and fixed PVC methods performed better than the Cook-Lodge and Chen methods.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies VII: Vascular Imaging
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)