Preliminary study of the detectability of coronary plaque with PET
G Delso1, A Martinez-Möller, R A Bundschuh
1Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, TU München, Ismaninger Str. 22, 81675 München, Germany. gaspar.delso@tum.de
Abstract:
The evaluation of coronary plaque vulnerability could be of great diagnostic value in cardiology. Positron emission tomography (PET) is a good candidate due to its ability to quantify micromolar concentrations of targeted drugs. However, the detectability of sub-voxel targets such as coronary plaque is limited by partial volume effects and by cardiorespiratory motion. The goal of this paper is to investigate the impact of these factors in the detectability of plaque uptake. Radioactive markers were implanted on the epicardium of a pig and in vivo scans were performed. This was complemented with phantom measurements to determine the minimum detectable uptake as a function of background activity. Simulations were used to evaluate the effect of cardiorespiratory motion on the reconstructed lesions. Despite cardiorespiratory motion of up to 7 mm, the markers were detectable in the in vivo scans even after the injection of background. A lower limit of 250 Bq was found for a target to be detectable. Motion reduced the contrast of the reconstructed lesions to 23% of their static counterpart. Respiratory gating improved this to 49% of the static value. The results suggest that coronary plaque evaluation with PET is possible, provided that sufficient plaque-to-myocardium uptake contrast (50 to 100) can be achieved. This requirement increases exponentially for lesions with uptake below 250 Bq. The described experiments provide a means of estimating the minimum uptake and contrast required to ensure the detectability of plaque lesions.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)