Related Experiment Video
Updated: Jun 3, 2026

Murine Model of Allergen Induced Asthma
Published on: May 14, 2012
A new approach to the determination of airway resistance: interrupter technique vs. plethysmography
Leandro Antônio Gritti1, Sérgio Saldanha Menna Barreto
1Department of Pulmonology, Porto Alegre Hospital de Clínicas, Universidade Federal do Rio Grande do Sul-UFRGS, Federal University of Rio Grande do Sul-Porto Alegre, Brazil. leandro@gritti.com.br
Objective:
To determine the agreement between interrupter resistance (Rint) and airway resistance (Raw) by plethysmography in order to verify the clinical applicability of the interrupter technique.
Methods:
The Rint technique was performed with the patients in a sitting position, during exhalation, with a nose clip and cheek support. Plethysmography was carried out in accordance with standard protocols. All measurements were taken prior to and after the administration of an inhaled bronchodilator via a metered dose inhaler with a spacer.
Results:
The study comprised 99 consecutive patients referred to the Porto Alegre Hospital de Clínicas, located in the city of Porto Alegre, Brazil, for pulmonary function testing. Patient ages ranged from 18 to 82 years, and 52 of the patients were women. In the patients with FEV1 ≥ 60% of predicted, there was good agreement between the methods (r = 0.8; intraclass correlation coefficient = 0.8). The Rint values were lower than were those of Raw by plethysmography in the patients with more severe disease. However, there was good agreement between Rint ≥ 4 cmH2O L(-1) s(-1) and Raw by plethysmography > 2.5 cmH2O L(-1) s(-1) (likelihood ratio > 8; kappa coefficient = 0.73).
Conclusions:
In the patients with less severe disease, there was good agreement between Rint and Raw by plethysmography. The agreement between the two methods was also strong regarding the detection of an increase in Raw. The Rint technique is a potentially useful method for the evaluation of adult patients.
More Related Videos
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
08:58Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...