Influence of arterial wall compliance on the pressure drop across coronary artery stenoses under hyperemic flow

Bhaskar Chandra Konala1, Ashish Das, Rupak K Banerjee

  • 1Department of Mechanical Engineering, University of Cincinnati, Cincinnati, OH 45221, USA.

Insights

Arterial wall compliance significantly impacts coronary artery pressure drop during hyperemic flow. Compliant models show lower pressure drops than rigid ones, potentially misdiagnosing stenosis severity.

Area of Science:

  • Biomedical Engineering
  • Cardiovascular Physiology
  • Computational Fluid Dynamics

Background:

  • Hemodynamic parameters like pressure drop are crucial for assessing coronary artery stenosis severity during angioplasty.
  • The influence of arterial wall and plaque compliance on pressure drop under hyperemic flow remains under-investigated.

Purpose of the Study:

  • To evaluate the effect of varying arterial-stenosis compliance on flow and pressure drop across different stenosis severities.
  • To compare pressure drop in rigid versus compliant arterial models under simulated hyperemic conditions.

Main Methods:

  • Utilized the Mooney-Rivlin model for non-linear material properties of arterial walls and plaque.
  • Employed the non-Newtonian Carreau model to simulate blood viscosity.
  • Solved fluid-structure interaction equations numerically using the finite element method.

Main Results:

  • Compliant models consistently yielded lower pressure drops compared to rigid models, irrespective of stenosis severity.
  • For 90% area occlusion, pressure drops were 41.0 mmHg (rigid), 32.1 mmHg (calcified plaque), and 29.8 mmHg (smooth muscle cell proliferation).
  • Significant reductions in pressure drop (27.7% and 37.6%) were observed in compliant models with calcified plaque and smooth muscle cell proliferation, respectively.

Conclusions:

  • Arterial and plaque compliance significantly alters pressure drop measurements in coronary lesions.
  • These variations can lead to misinterpretation and misdiagnosis of stenosis severity, especially in cases of significant occlusion.

Related Concept Videos

Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.