Related Experiment Video
Updated: Jun 3, 2026

Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Differences in breathing patterning during wakefulness in patients with mixed apnea-dominant vs obstructive-dominant
Motoo Yamauchi1, Shinji Tamaki1, Masanori Yoshikawa1
1Second Department of Internal Medicine, Department of Respiratory Medicine, Nara Medical University, Kashihara.
Background:
Mixed apneas share both central and obstructive components and are often treated as if they are obstructive events. The hypothesis is that patients with obstructive sleep apnea syndrome (OSAS) who exhibit a majority of mixed apneas will differ in ventilatory control from those with predominantly obstructive apneas during wakefulness; moreover, this difference could affect nasal continuous positive airway pressure (CPAP) adherence.
Methods:
In a retrospectively derived case-control study, 5 min of respiratory inductance plethysmography signals during wakefulness prior to sleep onset were extracted from a diagnostic polysomnogram in these groups: (1) mixed apnea-dominant OSAS (mix-OSAS) (n = 36), (2) obstructive apnea-dominant OSAS (pure-OSAS) (n = 20), (3) central apnea-dominant sleep apnea syndrome (pure-CSAS) (n = 6), and (4) control subjects (n = 10). Breathing patterning was compared between the groups using the coefficient of variation (CV) for breath-to-breath inspiration time (TI), expiration time (TE), TI + TE (Ttot), and tidal volume, and an information theory-based metric of signal pattern variability (sample entropy). Subsequent CPAP adherence over 12 months was determined in OSAS groups.
Results:
Breath-to-breath CV parameters and sample entropy in the mix-OSAS group were significantly greater as compared with the pure-OSAS and control groups. In a subanalysis, CV and sample entropy were similar in the mix-OSAS and the pure-CSAS groups. CPAP adherence was significantly poorer in mix-OSAS compared with pure-OSAS.
Conclusions:
During wakefulness, both breath patterning and sample entropy in mix-OSAS are similar to pure-CSAS and more variable than in pure-OSAS. In addition, CPAP adherence was decreased in patients with mix-OSAS, which may be related to basic differences in respiratory control.
More Related Videos
07:54Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Respiratory Volumes and Capacities I
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Sleep-Wake Cycles
NREM Sleep
NREM sleep comprises four progressive stages that seamlessly merge:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...