Background And Purpose:
The purpose of this study was to design a radiation therapy treatment planning approach that would spare hematopoietically active bone marrow using [(18)F]FLT PET imaging.
Materials And Methods:
We have developed an IMRT planning methodology to incorporate functional PET imaging using [(18)F]FLT scans. Plans were generated for two simulated cervical cancer patients, where pelvic active bone marrow regions were incorporated as avoidance regions based on the ranges: SUV4 ≥ 4; 4>SUV3 ≥ 3; and 3 > SUV2 ≥ 2. Dose objectives were set to reduce bone marrow volume that received 10 (V(10)) and 20 (V(20))Gy.
Results:
Active bone marrow regions identified by [(18)F]FLT with an SUV ≥ 2, SUV ≥ 3, and SUV ≥ 4 represented an average of 43.0%, 15.3%, and 5.8%, respectively of the total osseous pelvis for the two cases studied. Improved dose-volume histograms for all identified bone marrow SUV volumes and decreases in V(10), and V(20) were achieved without clinically significant changes to PTV or OAR doses.
Conclusions:
Incorporation of [(18)F]FLT PET in IMRT planning provides a methodology to reduce radiation dose to active bone marrow without compromising PTV or OAR dose objectives in pelvic malignancies.