Objective:
To determine normal arterial oxygen saturation (SpO(2)) trend during first 30 min of life and to evaluate for difference in SpO(2) trends in healthy term newborns of normal vaginal delivery (NVD) and elective cesarean section (CS).
Methods:
This Prospective Cross-sectional Observational study was conducted in Department of Pediatrics and Obstetrics, Gandhi Medical College, Bhopal. Newborns born of NVD and elective CS in first 30 min of life, complying with the study criteria were included in the study. Soon after birth, newborns with Apgar score ≥ 7 were given routine care and pulse-oximeter probe was applied on wiped right hand continuously for 30 min. Readings were obtained at an interval of 5 min.
Results:
Among NVD, the mean SpO(2) at 1, 5, 10, 15, 20, 25 and 30 min were 64.26%, 76.23%, 86.05%, 90.78%, 91.41%, 91.73% and 93.48%, respectively. The mean SpO(2) for CS was 67.43%, 78.50%, 88.44%, 90.81%, 91.46%, 91.83% and 92.88%, respectively. There was no significant difference in the SpO(2) between NVD and CS [95% CI = 74.8612-94.8359 in NVD and 77.1231-94.6912 in CS] and the correlation between NVD and CS being significant [r = 0.997 at 0.01 level]. There exists a strong positive correlation between Apgar and SpO(2) [r = 0.995, significant at 0.01 level (1-tailed) in NVD and r = 0.980, significant at 0.01 level (2-tailed) in CS].
Conclusions:
The study defines the normal SpO(2) in healthy term newborns of NVD and CS delivered newborns and also concludes that there is no significant difference in SpO(2) among NVD and CS.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...