Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps
Jesse M Ehrenfeld1, Richard H Epstein, Stephen Bader
1Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA. jehrenfe@post.harvard.edu
Background:
Arterial blood pressure (BP) measurement at least every 5 minutes is part of the American Society of Anesthesiologists' monitoring standard, but prolonged BP gaps in electronic anesthesia records have been noted. We undertook multicenter studies to determine the frequency of cases with at least 1 interval ≥10 minutes between successive BP measurements and then to ascertain whether educational feedback via an electronic, near real-time notification system alerting providers to the presence of such gaps would reduce their incidence.
Methods:
We evaluated 212,706 electronic anesthesia records from 3 large academic centers. We determined the fraction of cases with ≥10-minute BP monitoring gaps at baseline and did a root cause analysis to determine common causes for these lapses. We then designed and implemented automated systems at 2 of the hospitals to notify point-of-care providers immediately after such 10-minute gaps occurred and determined the subsequent impact of this feedback on BP gap incidence, compared with baseline.
Results:
At Hospital A, the notification system reduced the incidence of cases with at least 1 BP gap (1.48%± 0.19% SD vs 0.79% ± 0.36% SD, P < 0.0001). At Hospital B, the gap incidence was not significantly altered when notification was provided after a 10-minute gap had already occurred (2.72% ± 0.60% SD vs 2.45% ± 0.48% SD, P = 0.27), but the incidence was reduced when such notification was provided after 6 minutes without a BP reading (2.72% ± 0.60% SD vs 1.54% ± 0.19% SD, P < 0.0001). At Hospital C, where notification was not implemented, the baseline rate of BP gaps was consistent across the preintervention and follow-up periods (7.03% ± 1.27% SD vs 7.13% ± 0.11% SD, P = 0.74). Although monitors disconnected during position change was the most common identifiable cause of BP gaps, reasons for the missing BP measurements were often not documented. During a week when the electronic charting system was temporarily inoperable, no BP gaps were noted on a convenience sample of 500 paper records from Hospital A (99% upper confidence limit = 0.83%).
Conclusions:
BP gaps of ≥10 minutes were common in electronic anesthesia records, and their incidence was reduced but not eliminated by near real-time feedback to providers. The American Society of Anesthesiologists' standard for BP documentation every 5 minutes might not be achievable with current practices and technology. Anesthesia information management systems users need to be cognizant of the potential for gaps in BP measurement, take steps to minimize their occurrence, and document an explanation when such failures occur.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Stages of General Anesthesia