Related Experiment Video
Updated: Jun 3, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Specific screening method for dextran and hydroxyethyl starch in human urine by size exclusion
Marjo Kolmonen1, Antti Leinonen, Tiia Kuuranne
1Hjelt Institute, Department of Forensic Medicine, Forensic Toxicology Division, University of Helsinki, Helsinki, Finland.
Abstract:
The use of plasma volume expanders (PVE), such as dextran (DEX) and hydroxyethyl starch (HES), is prohibited in sports. DEX is a naturally occurring glucose polymer, whereas HES is synthetically produced from amylopectin starch by substitution with hydroxyethyl groups. In doping control, the commonly applied enzymatic and colorimetric screening methods are lacking adequate specificity for DEX and HES. Also, gas chromatographic-mass spectrometic (GC-MS) screening methods have specificity issues with DEX. In addition, due to the nature of the target compounds, time-consuming derivatisation steps are required in GC-MS. Based on the high molecular weight of carbohydrate polymers excreted in urine after administration of DEX and HES, a screening method was developed involving size exclusion chromatography (SEC) combined with time-of-flight mass spectrometry (TOFMS). By using solely a SEC guard column as an analytical column allowed sufficient chromatographic resolution in a minimal amount of time and with reasonable repeatability (average RSD of 10%). Detector response was linear throughout the measurement range with R(2) > 0.99 for both analytes. Limits of detection were 100 and 250 μg mL(-1) for DEX and HES, respectively. Ion suppression was found to be 52% at maximum. In-source collision-induced dissociation (ISCID) was used to produce characteristic fragments at a mass accuracy better than 2 mDa. The specificity of the SEC-ISCID-TOFMS method was demonstrated with 120 PVE negative doping control samples analyzed in parallel with a routine GC-MS screening method. In addition, seven urine samples from diabetic athletes, causing interpretation problems in routine GC-MS, showed here a definitely negative profile.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors