Related Experiment Video
Updated: Jun 3, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
[Effects of different reference point on intra-abdominal pressure measurement in critically ill patients: a clinical
Tian Liu1, Song-Qiao Liu, Ling Liu
1Department of Critical Care Medicine, Zhongda Hospital, Southeast University, Nanjing 210009, China.
Objective:
To investigate the effects of different reference point on intra-abdominal pressure (IAP) measurement.
Methods:
Nine critically ill patients with risk of intra-abdominal hypertension (IAH) were studied from July 2008 to June 2010, all of the patients were equipped with abdominal cavity drain and urinary drainage tube. By which IAP was measured using direct and indirect methods respectively. The symphysis pubis, phlebostatic axis and the midaxillary line at the level of the iliac crest were defined as reference points. According to the different reference point, three sets of IAP measurements were obtained in the supine position with each method and kept as IAP(S), IAP(P), IAP(I). Bland-Altman method analysis and Pearson's correlation were performed to evaluate the relationships between results from different reference points with direct and indirect methods. Paired t-test was performed to evaluate the differences among different reference points.
Results:
Sixty measurements of IAP(S), IAP(P) and IAP(I) were obtained. In direct measurement through abdominal cavity drain, IAP(I) (13.8 ± 3.9) mmHg (1 mmHg = 0.133 kPa) was significantly higher than IAP(P) (12.8 ± 3.6) mmHg and IAP(S) (9.1 ± 3.6) mmHg, P < 0.05; while in indirect measurement through urinary drainage tube, IAP(I) (12.7 ± 3.2) mmHg was significantly higher than IAP(P) (11.7 ± 2.9) mmHg and IAP(S) (7.9 ± 3.0) mmHg too, P < 0.05. In either direct or indirect method, IAP(P) was higher than IAP(S), P < 0.05. And good correlations were found among IAP(S), IAP(P) and IAP(I).
Conclusions:
In the supine position, pressure obtained via the bladder could reflect authentic IAP. But selection of reference point has great impact on IAP measurement.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.