Purpose:
Computed tomography pulmonary angiography (CTPA) is considered as clinical gold standard for diagnosing pulmonary embolism (PE). Whereas conventional CTPA only offers anatomic information, dual energy CT (DECT) provides functional information on blood volume as surrogate of perfusion by assessing the pulmonary iodine distribution. The purpose of this study was to evaluate the feasibility of lung perfusion imaging using a single-tube DECT scanner with rapid kVp switching.
Materials And Methods:
Fourteen patients with suspicion of acute PE underwent DECT. Two experienced radiologists assessed the CTPA images and lung perfusion maps regarding the presence of PE. The image quality was rated using a semi-quantitative 5-point scale: 1 (=excellent) to 5 (=non-diagnostic). Iodine concentrations were quantified by a ROI analysis.
Results:
Seventy perfusion defects were identified in 266 lung segments: 13 (19%) were rated as consistent with PE. Five patients had signs of PE at CTPA. All patients with occlusive clots were correctly identified by DECT perfusion maps. On a per patient basis the sensitivity and specificity were 80.0% and 88.9%, respectively, while on a per segment basis it was 40.0% and 97.6%, respectively. None of the patients with a homogeneous perfusion map had an abnormal CTPA. The overall image quality of the perfusion maps was rated with a mean score of 2.6 ± 0.6. There was a significant ventrodorsal gradient of the median iodine concentrations (1.1mg/cm(3) vs. 1.7 mg/cm(3)).
Conclusion:
Lung perfusion imaging on a DE CT-system with fast kVp-switching is feasible. DECT might be a helpful adjunct to assess the clinical severity of PE.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pulmonary Embolism I: Introduction
Pulmonary Embolism I: Introduction