Related Experiment Video
Updated: Jun 3, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Development of a dosimetry inter-comparison for IMRT as part of site credentialing for a TROG multi-centre clinical
1Radiation Oncology Queensland, Toowoomba, Australia. brendan.healy@roq.net.au
A methodology has been developed for a dosimetry inter-comparison of intensity modulated radiation therapy (IMRT) delivery in Australasia. The inter-comparison is part of site credentialing for those sites participating in the prostate fractionated irradiation trial (PROFIT) for intermediate-risk prostate patients developed by the Ontario Clinical Oncology Group and coordinated in Australasia by the Trans Tasman Radiation Oncology Group. Features of the dosimetry inter-comparison design included the use of a dedicated pelvic anthropomorphic phantom, the use of a single CT data set of the phantom including contours and the use of radiochromic film as a dosimeter. Action levels for agreement between measured dose and treatment planning system dose have been proposed based on measurement uncertainty and international experience. A trial run of the dosimetry procedure at the reference centre gave results within the predefined action levels.
A methodology has been developed for a dosimetry inter-comparison of intensity modulated radiation therapy (IMRT) delivery in Australasia. The inter-comparison is part of site credentialing for those sites participating in the prostate fractionated irradiation trial (PROFIT) for intermediate-risk prostate patients developed by the Ontario Clinical Oncology Group and coordinated in Australasia by the Trans Tasman Radiation Oncology Group. Features of the dosimetry inter-comparison design included the use of a dedicated pelvic anthropomorphic phantom, the use of a single CT data set of the phantom including contours and the use of radiochromic film as a dosimeter. Action levels for agreement between measured dose and treatment planning system dose have been proposed based on measurement uncertainty and international experience. A trial run of the dosimetry procedure at the reference centre gave results within the predefined action levels.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020