Related Experiment Video
Updated: Jun 3, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Detection of valve malfunction after mechanical MVR using digital phonocardiography
M Schlömicher1, A Brensing, A Laczkovics
1Department of Cardiothoracic Surgery, Ruhr University Hospital Bergmannsheil Bochum, Bochum, Germany. markus.schloemicher@bergmannsheil.de
Abstract:
We present the case of a 63-year-old female patient who developed severe chronic dyspnea two years after mechanical mitral valve replacement (MVR). Conventional cardiac diagnostics including echocardiography, fluoroscopy, right and left heart catheterization could not detect any malfunction. Only digital phonocardiography was able to show alterations of the typical acoustic signal. Based on the symptoms, the clinical history and these abnormal findings the decision was taken to reoperate. Intraoperatively, a ruptured tendinous chord was found, impeding the inferior leaflet. Redo MVR was performed.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: