Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Test battery for assessing vascular disturbances of fingers
1University of Cincinnati Medical Center, PO Box 670840, 45267-0840, Cincinnati, Ohio, USA, christopher.lindsell@uc.edu.
Abstract:
The diagnosis of vibration-induced white finger (VWF) is difficult, often relying on medical interview and history. The condition is characterized by an exaggerated vasoconstriction of digital arteries in response to cold. The complete closure of digital arteries is episodic and results in a characteristic blanching that is rarely observed by a clinician. Objective measurements of the response of the digital circulation to cold can assist in evaluating a patient for VWF. Finger systolic blood pressure (FSBP) following local cooling is a measure of cold-induced vasoconstriction in digital arteries and is an assessment of vasomotor tone. Low FSBPs following cooling are indicative of dysfunction. Finger skin temperature (FST) following hand cooling is a measure of cutaneous blood flow. The mechanism underlying the recovery of cutaneous blood flow following cooling is as yet not fully understood, but a delayed recovery is believed to arise from persistent vascular disturbances of the fingers or from a resulting in conflicting opinions concerning the utility of the measurements, a scarcity of comparable data from epidemiological investigations, and limited normative data to aid clinicians in decision-making. This review of evidence on which the tests are based is aimed at providing clinicians and researchers with an understanding of the factors that must be considered when conducting the tests, interpreting the results, and comparing results between different studies.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: