PDE-based random-valued impulse noise removal based on new class of controlling functions

Jian Wu1, Chen Tang

  • 1Department of Applied Physics, Tianjin University, Tianjin 300072, China. wudging@mail.jxau.edu.cn

Related Concept Videos

Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the system's...
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Random Variables01:09

Random Variables

A random variable is a single numerical value that indicates the outcome of a procedure. The concept of random variables is fundamental to the probability theory and was introduced by a Russian mathematician, Pafnuty Chebyshev, in the mid-nineteenth century.
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Basic Continuous Time Signals01:22

Basic Continuous Time Signals

Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Sampling Continuous Time Signal01:11

Sampling Continuous Time Signal

In signal processing, a continuous-time signal can be sampled using an impulse-train sampling technique, followed by the zero-order hold method. Impulse-train sampling involves the use of a periodic impulse train, which consists of a series of delta functions spaced at regular intervals determined by the sampling period. When a continuous-time signal is multiplied by this impulse train, it generates impulses with amplitudes corresponding to the signal's values at the sampling points.
In the...