Related Experiment Video
Updated: Jun 3, 2026

Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
Binocular visual simulation of a corneal inlay to increase depth of focus
Juan Tabernero1, Christina Schwarz, Enrique J Fernández
1Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain. juant@um.es
Purpose:
To investigate binocular visual acuity and depth of focus when one eye forms images through a typical pupil diameter aperture (4 mm) and the other eye through a small pupil of 1.5-mm diameter.
Methods:
Using a recently developed adaptive optics binocular visual simulator, through focus monocular and binocular visual acuity were measured in three subjects under specially simulated visual conditions: right eyes had "small aperture" vision through a 1.5-mm pupil diameter and left eyes had normal vision through 4-mm pupil diameter. The measurements were performed in photopic and mesopic conditions.
Results:
An increase in binocular and monocular (for the small-aperture eye) depth of focus was measured with respect to the 4-mm pupil diameter eye. It ranged from 1 to 1.5 diopter (D) depending on the threshold requirement and the visibility conditions. For photopic conditions, the J2 visual acuity level was reached at 1 D of defocus for the 4-mm pupil diameter case, while for the 1.5-mm, the J2 level was reached at 2.5 D. Binocular summation occurred only in far vision conditions (no defocus added). For near vision, binocular visual acuity closely followed the values of monocular visual acuity for the eye with the smaller aperture.
Conclusions:
The small-aperture effect to increase depth of focus in the human eye was successfully implemented in a binocular visual simulator. Although certain limitations exist, the small-aperture approach provided a simple but attractive solution to increase depth of focus in the human eye.
More Related Videos
08:13In Vivo Confocal Microscopy in the Diagnosis and Management of Dry Eye: A Focus on Imaging Protocols and Interpretation
Published on: November 11, 2025
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
Related Concept Videos
Focusing of Light in the Eye
Depth Perception and Spatial Vision