A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Toward noninvasive blood pressure assessment in arteries by using ultrasound
Bart W A M M Beulen1, Nathalie Bijnens, Gregory G Koutsouridis
1Section Cardiovascular Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Abstract:
A new method has been developed to measure local pressure waveforms in large arteries by using ultrasound. The method is based on a simultaneous estimation of distension waveforms and velocity profiles from a single noninvasive perpendicular ultrasound B-mode measurement. Velocity vectors were measured by applying a cross-correlation based technique to ultrasound radio-frequency (RF) data. From the ratio between changes in flow and changes in cross-sectional area of the vessel, the local pulse wave velocity (PWV) was estimated. This PWV value was used to convert the distension waveforms into pressure waveforms. The method was validated in a phantom set-up. Physiologically relevant pulsating flows were considered, employing a fluid which mimics both the acoustic and rheologic properties of blood. A linear array probe attached to a commercially available ultrasound scanner was positioned parallel to the vessel wall. Since no steering was used, the beam was perpendicular to the flow. The noninvasively estimated pressure waveforms showed a good agreement with the reference pressure waveforms. Pressure values were predicted with a precision of 0.2 kPa (1.5 mm Hg). An accurate beat to beat pressure estimation could be obtained, indicating that a noninvasive pressure assessment in large arteries by means of ultrasound is feasible.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure