Related Experiment Video
Updated: Jun 3, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts. Determination of
Ariel R Fontana1, Alejandra Camargo, Luis D Martinez
1Grupo de Investigación y Desarrollo en Química Analítica (QUIANID) (LISAMEN, CCT CONICET-Mendoza), Mendoza, Argentina.
Abstract:
Dispersive solid-phase extraction (DSPE) is proposed for the first time as a simplified, fast and low cost clean-up technique of biological sample extracts for polybrominated diphenyl ethers (PBDEs) determination. The combination of a traditional extraction technique, such as ultrasound-assisted leaching (USAL) with DSPE was successfully applied for sample preparation prior to gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. The analytes were first extracted from 1g homogenized sample in n-hexane:dichloromethane (8:2) by applying USAL technique and further cleaned-up using DSPE with 0.20 g C(18)-silica as sorbent material. Different solvent mixtures, sorbent type and amount, and lipid digestion procedures were evaluated in terms of clean-up and extraction efficiency. Under optimum conditions, the method detection limits (MDLs) for PBDEs, calculated as three times the signal-to-noise ratio (S/N) were within the range 9-44 pg g(-1) wet weight. The calibration graphs were linear within the concentration range of 53-500,000 pg g(-1), 66-500,000 pg g(-1), 89-500,000 pg g(-1) and 151-500,000 pg g(-1) for BDE-47, BDE-100, BDE-99 and BDE-153, respectively; and the coefficient of determination (r(2)) exceeded 0.9992 for all analytes. The proposed methodology was compared with a reference solid-phase extraction technique. The applicability of the methodology for the screening of PBDEs has been demonstrated by analyzing spiked and real samples of biological nature (fish, egg and chicken) with different lipid content as well as reference material (WELL-WMF-01). Recovery values ranged between 75% and 114% and the measured concentrations in certified material showed a reasonable agreement with the certified ones. BDE-47, BDE-100 and BDE-99 were quantified in three of the seven analyzed samples and the concentrations ranged between 91 and 140 pg g(-1). In addition, this work is the first description of PBDEs detected in fish of Argentinean environment.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...