Related Experiment Video
Updated: Jun 3, 2026

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Is there any maximum standardized uptake value variation among positron emission tomography scanners for mediastinal
Ilker Iskender1, Salih Zeki Kadioglu, Altug Kosar
1Department of Thoracic Surgery, Cizre Dr. Selahattin Cizrelioglu State Hospital, Sirnak, Turkey. ilker.iskender@yahoo.ca
Abstract:
The maximum standardized uptake value (SUV(max)) varies among positron emission tomography-integrated computed tomography (PET/CT) centers in the staging of non-small cell lung cancer. We evaluated the ratio of the optimum SUV(max) cut-off for the lymph nodes to the median SUV(max) of the primary tumor (ratioSUV(max)) to determine SUV(max) variations between PET/CT scanners. The previously described PET predictive ratio (PPR) was also evaluated. PET/CT and mediastinoscopy and/or thoracotomy were performed on 337 consecutive patients between September 2005 and March 2009. Thirty-six patients were excluded from the study. The pathological results were correlated with the PET/CT findings. Histopathological examination was performed on 1136 N2 lymph nodes using 10 different PET/CT centers. The majority of patients (group A: 240) used the same PET/CT scanner at four different centers. Others patients were categorized as group B. The ratioSUV(max) for groups A and B was 0.18 and 0.22, respectively. The same ratio for centers 1, 2, 3 and 4 was 0.2, 0.21, 0.21, and 0.23, respectively. The optimal cut-off value of the PPR to predict mediastinal lymph node pathology for malignancy was 0.49 (likelihood ratio +2.02; sensitivity 70%, specificity 65%). We conclude that the ratioSUV(max) was similar for different scanners. Thus, SUV(max) is a valuable cut-off for comparing-centers.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

