Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Quantum-Optimal Frequency Estimation of Stochastic ac Fields.

Physical review letters·2025
Same author

The Effect of Trap Design on the Scalability of Trapped-Ion Quantum Technologies.

Entropy (Basel, Switzerland)·2025
Same author

Probing Rotational Decoherence with a Trapped-Ion Planar Rotor.

Physical review letters·2025
Same author

Spectral control of nonclassical light pulses using an integrated thin-film lithium niobate modulator.

Light, science & applications·2022
Same author

Surface Plasmon Enhanced Upconversion Fluorescence in Short-Wave Infrared for In Vivo Imaging of Ovarian Cancer.

ACS nano·2022
Same author

Spectrally separable photon-pair generation in dispersion engineered thin-film lithium niobate.

Optics letters·2022
Same journal

Denoising algorithm of Φ-OTDR systems based on adaptive fractional wavelet transform denoising.

Optics express·2026
Same journal

Millisecond photon-to-photon latency and high-speed volumetric projection system for optogenetics.

Optics express·2026
Same journal

Polarization-encoded coaxial structured light for high-precision 3D surface profilometry.

Optics express·2026
Same journal

Discrete freeform optical design based on collaborative optimization of point cloud and local normals.

Optics express·2026
Same journal

Ultrafast ghost imaging with 25 GHz speckle switching and wavelength-division multiplexing.

Optics express·2026
Same journal

Atomic vapor cells fabricated by femtosecond laser welding of standard-optical-quality glass.

Optics express·2026
See all related articles

Related Experiment Video

Updated: Jun 3, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Achieving sub-Rayleigh resolution via thresholding.

Sara Mouradian1, Franco N C Wong, Jeffery H Shapiro

  • 1Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA. smouradi@mit.edu

Optics Express
|March 30, 2011
PubMed
Summary
This summary is machine-generated.

Researchers achieved imaging resolution beyond the conventional Rayleigh limit. This was done by scanning a laser beam and applying a dynamic threshold, enhancing spatial resolution beyond physical limitations.

More Related Videos

Test Samples for Optimizing STORM Super-Resolution Microscopy
16:52

Test Samples for Optimizing STORM Super-Resolution Microscopy

Published on: September 6, 2013

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging
07:15

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging

Published on: July 11, 2025

Related Experiment Videos

Last Updated: Jun 3, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Test Samples for Optimizing STORM Super-Resolution Microscopy
16:52

Test Samples for Optimizing STORM Super-Resolution Microscopy

Published on: September 6, 2013

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging
07:15

Transient Optical Clearing Using Absorbing Molecules for Ex Vivo and In Vivo Imaging

Published on: July 11, 2025

Area of Science:

  • Optics and Photonics
  • Imaging Science

Background:

  • Conventional imaging systems are limited by diffraction, specifically the Rayleigh resolution limit imposed by the finite diameter of the entrance pupil.
  • This fundamental limit restricts the ability to distinguish fine details in images.

Purpose of the Study:

  • To demonstrate and quantify spatial resolution enhancement beyond the established Rayleigh limit.
  • To explore a novel imaging technique that circumvents traditional diffraction limitations.

Main Methods:

  • Utilizing unstructured scanning of a focused laser beam across an object.
  • Dynamically applying a threshold (N) below the maximum count level (Nmax) during image acquisition.

Main Results:

  • Experimental validation of spatial resolution exceeding the Rayleigh bound.
  • Quantified resolution enhancement by a factor of [ln(Nmax/N)]1/2, demonstrating a significant improvement.

Conclusions:

  • The proposed method successfully overcomes the Rayleigh resolution limit in imaging systems.
  • This technique offers a pathway to achieve super-resolution imaging through dynamic thresholding and beam scanning.