Related Experiment Video
Updated: Jun 3, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Application of chlorine dioxide for disinfection of student health centers
Ching-Shan Hsu1, Ming-Chun Lu, Da-Ji Huang
1Department of Environmental Resource Management, Chia-Nan University of Pharmacy and Science, Tainan 71710, Taiwan. hsuhsu@mail.chna.edu.tw
Abstract:
In Taiwan, the immediate health care requirements of students and faculty members are satisfied by on-campus medical service centers. The air quality within these centers should comply with the guidelines laid down by the Taiwan Environmental Protection Agency (EPA). Accordingly, this study performed an experimental investigation into the efficiency of various chlorine dioxide applications in disinfecting a local student health center (SHC). The air quality before and after disinfection were evaluated in terms of the bioaerosol levels of bacteria and fungi. The average background levels of bacteria and fungi before disinfection were found to be 1,142 ± 455.4 CFU/m(3) and 520 ± 442.4 CFU/m(3), respectively. Chlorine dioxide (0.3 mg/m(3)) was applied using three different methods, namely a single, one-off application, multiple applications within a single day, and regular (daily) applications. Among the three disinfection methods, the regular application method was found to yield a high disinfection efficiency for both bacteria and fungi, i.e., 6.5 ± 0.7% and 4.2 ± 0.3%, respectively. The average residual bacteria and fungi levels after regular daily interval disinfection were 318.8 ± 51.5 CFU/m(3) and 254.0 ± 43.8 CFU/m(3), respectively. Therefore, the results suggest that the air quality guidelines prescribed by the Taiwan EPA for SHCs and other healthcare facilities can best be achieved by applying chlorine dioxide at regular (daily) intervals.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration