Related Experiment Video
Updated: Feb 10, 2026

A Porcine Model of Acute Autologous Pulmonary Embolism
Published on: September 6, 2024
Super-micro-bland particle embolization combined with RF-ablation: angiographic, macroscopic and microscopic features
C M Sommer1, N Kortes, C Mogler
1Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg, Germany. christof.sommer@med.uni-heidelberg.de
Purpose:
To describe angiographic, macroscopic and microscopic features of super-micro-bland particle embolization in combination with RF-ablation in kidneys. Thereby, a special focus was given on the impact of the sequence of the different procedural steps.
Materials And Methods:
In ten pigs, super-micro-bland particle embolization combined with RF-ablation was carried out. Super-micro-bland embolization was performed with spherical particles of very small size and tight calibration (40 ± 10 μm). In the left kidneys, RF-ablations were performed before embolization (I). In the right kidneys, RF-ablations were performed after embolization (II). The animals were killed three hours after the procedures. Angiographic (e.g. vessel architecture), macroscopic (e.g. long and short axes of the RF-ablations) and microscopic (e.g. particle distribution) study goals were defined.
Results:
Angiography detected almost no vessels in the center of the RF-ablations in I. In II, angiography could not define the RF-ablations. Macroscopy detected significantly larger long and short axes of the RF-ablations in II compared to I (52.2 ± 3.2 mm vs. 45.3 ± 6.9 mm [P<0.05] and 25.1 ± 3.5mm vs. 20.0 ± 1.9 mm [P<0.01], respectively). Microscopy detected irregular particle distribution at the rim of the RF-ablations in I. In II, microscopy detected homogeneous particle distribution at the rim of the RF-ablations. Microscopy detected no particles in the center of the RF-ablations in I and II.
Conclusion:
The sequence of the different procedural steps of super-micro-bland particle embolization combined with RF-ablation impacts angiographic, macroscopic and microscopic features in kidneys in the acute setting.
Related Concept Videos
Pulmonary Embolism I: Introduction
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Kidney Structure
Subatomic Particles
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
Super-resolution Fluorescence Microscopy

