Related Experiment Video
Updated: Jun 3, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Can experienced CT radiologists use technique parameters to predict excessive patient dose? An analysis of the ACR CT
Robert K Zeman1, Vincent Herlihy, Theresa A Branham
1George Washington University Medical Center, Washington, District of Columbia 20037, USA. gwuradrz@yahoo.com
Purpose:
The aim of this study was to determine, for 3 basic clinical examinations, whether blinded, experienced CT radiologists participating in the ACR's CT Accreditation Program could use scan parameters such as tube current-time product (mAs), tube voltage (kVp), and pitch to predict scanner output settings, expressed as weighted CT dose index (CTDIw) and volume CT dose index (CTDIvol), exceeding CTDIw diagnostic reference levels (DRLs) set by the ACR in 2002 and CTDIvol DRLs adopted by the ACR in 2008.
Methods:
CT sites with 829 scanners submitted examinations to the ACR between 2002 and 2004, yielding 518 eligible examinations for analysis (138 adult head CT scans, 333 adult abdominal CT scans, and 47 pediatric abdominal CT scans). The sites' measured CTDIw values for each type of examination were compared with the ACR's CTDIw DRLs in effect from 2002 to 2004 and compared with comments regarding excessively high mAs or kVp made by radiologist clinical reviewers to determine if excessively high-dose index measurements could be predicted. The same analysis was repeated using CTDIvol DRLs adopted by the ACR in 2008 and compared with excessively high mAs or kVp and excessively low-pitch comments.
Results:
Excessively high mAs or kVp comments yielded sensitivity of only 21.2% in predicting examinations above the CTDIw DRLs, with specificity of 87.6%. Using the 2008 CTDIvol DRLs, the corresponding sensitivity was 13.1% and specificity was 86.2%. Significance was not achieved for use of clinical parameters in predicting either the CTDIw or CTDIvol.
Conclusion:
Experienced CT radiologists cannot reliably use scan parameters to predict examinations that exceed CTDIw or CTDIvol DRLs.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
05:18Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
Published on: October 6, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography