Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
Contributions of optical and non-optical blur to variation in visual acuity
J Jason McAnany1, Mahnaz Shahidi, Raymond A Applegate
1Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, Illinois, USA. jmcana1@uic.edu
Purpose:
To determine the relative contributions of optical and non-optical sources of intrinsic blur to variations in visual acuity (VA) among normally sighted subjects.
Methods:
Best-corrected VA of 16 normally sighted subjects was measured using briefly presented (59 ms) tumbling E optotypes that were either unblurred or blurred through convolution with Gaussian functions of different widths. A standard model of intrinsic blur was used to estimate each subject's equivalent intrinsic blur (σint) and VA for the unblurred tumbling E (MAR0). For 14 subjects, a radially averaged optical point spread function due to higher-order aberrations was derived by Shack-Hartmann aberrometry and fit with a Gaussian function. The standard deviation of the best-fit Gaussian function defined optical blur (σopt). An index of non-optical blur (η) was defined as 1 - σopt/σint. A control experiment was conducted on five subjects to evaluate the effect of stimulus duration on MAR0 and σint. RESULTS.: The logarithm of the minimum angle of resolution (logMAR₀) for the briefly presented E was correlated significantly with log σint (r = 0.95, p < 0.01), consistent with previous work. However, logMAR₀ was not correlated significantly with log σopt (r = 0.46, p = 0.11). For subjects with logMAR₀ equivalent to ~20/20 or better, logMAR₀ was independent of log η, whereas for subjects with larger logMAR₀ values, logMAR₀ was proportional to log η. The control experiment showed a statistically significant effect of stimulus duration on logMAR₀ (p < 0.01) but a non-significant effect on σint (p = 0.13).
Conclusions:
The relative contributions of optical and non-optical blur to VA varied among the subjects and were related to the subject's VA. Evaluating optical and non-optical blur may be useful for predicting changes in VA following procedures that improve the optics of the eye in patients with both optical and non-optical sources of VA loss.
Related Concept Videos
Focusing of Light in the Eye
Depth Perception and Spatial Vision
Photoreceptors and Visual Pathways
Vision
Anatomy of the Eyeball
Visual System
Once through the pupil, the light passes through the lens, a...