Related Experiment Video
Updated: Jun 3, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Health care workers and respiratory protection: is the user seal check a surrogate for respirator fit-testing?
Quinn Danyluk1, Chun-Yip Hon, Mike Neudorf
1Workplace Health, Fraser Health, Burnaby, BC, Canada. quinn.danyluk@fraserhealth.ca
Abstract:
Many agencies recommend that health care workers wear N95 filtering facepiece respirators (N95-FFR) to minimize occupational exposure to bioaerosols, such as tuberculosis and pandemic influenza. Published standards outline procedures for the proper selection of an N95-FFR model, including user seal checks and respirator fit-testing. Some health officials have argued that the respirator fit-test step should be eliminated altogether, given its additional time and cost factors, and that only a user seal check be utilized to ensure that an adequate face seal has been achieved. One of the aims of the current study is to examine whether a user seal check is an appropriate surrogate for respirator fit-testing. Subjects were assigned an N95-FFR and asked to perform a user seal check (as per manufacturer's instructions) after which they immediately underwent a respirator fit-test. Successfully passing a respirator fit-test was based on not detecting a leakage through the face seal (either qualitatively with a test agent or quantitatively with a particulate counter). The sample population consisted of 647 subjects who had never been previously fit-tested (naive), while the remaining 137 participants were experienced respirator users. Only four of the 647 naive subjects (0.62%) identified an inadequate seal during their user seal check. Of the 643 remaining naive subjects who indicated that they had an adequate face seal prior to fit-testing, 158 (25%) failed the subsequent quantitative fit-test and 92 (14%) failed the qualitative fit-test. All 137 experienced users indicated that they had an adequate seal after performing the user seal check; however, 41 (30%) failed the subsequent quantitative fit-test, and 30 (22%) failed the qualitative fit-test. These findings contradict the argument to eliminate fit-testing and rely strictly on a user seal check to evaluate face seal.
Related Concept Videos
PPE Use in Healthcare Settings I: Donning
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Personal Protective Equipment
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and key...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...

