Related Experiment Video
Updated: Jun 3, 2026

Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo
Published on: September 26, 2016
A fast integral equation method for simulating high-field radio frequency coil arrays in magnetic resonance imaging
Shumin Wang1, Jacco A de Zwart, Jeff H Duyn
1Department of Electrical and Computer Engineering, Auburn University, 200 Broun Hall, Auburn, AL 36849, USA. james.wang@ieee.org
Abstract:
A fast full-wave numerical approach was developed for simulating high-field multi-channel radio-frequency (RF) receive coil arrays in magnetic resonance imaging. To improve the efficiency, the impedance matrix was compressed by a multilevel adaptive cross approximation method. Furthermore, careful organization of multiple coil simulations was applied so that the impedance matrix associated with biological subjects is constructed and pre-conditioned only once. Numerical examples demonstrate the efficacy of the proposed approach for RF coil simulations.
Related Concept Videos
Atomic Nuclei: Magnetic Resonance
Magnetic Resonance Imaging
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Plane Electromagnetic Waves II