Issues of discontinuity in the impulse residue function for deconvolution analysis of dynamic contrast-enhanced MRI

T S Koh1, D L H Cheong, Z Hou

  • 1Department of Oncologic Imaging, National Cancer Center, Singapore 169610, Singapore. koh.t.s@nccs.com.sg

Related Concept Videos

Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Improper Integrals: Discontinuous Integrands01:28

Improper Integrals: Discontinuous Integrands

Evaluating Areas Under Curves with DiscontinuitiesA definite integral is considered improper when the integrand is discontinuous at one of the limits of integration. This occurs when the function is undefined or becomes infinite at an endpoint, making the corresponding region under the curve unbounded. Such behavior is commonly associated with vertical asymptotes at the boundary of the interval. To properly define and evaluate these integrals, a limiting process is used to determine whether a...
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Convolution: Math, Graphics, and Discrete Signals01:24

Convolution: Math, Graphics, and Discrete Signals

In any LTI (Linear Time-Invariant) system, the convolution of two signals is denoted using a convolution operator, assuming all initial conditions are zero. The convolution integral can be divided into two parts: the zero-input or natural response and the zero-state or forced response, with t0 indicating the initial time.
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...
Convolution Properties II01:17

Convolution Properties II

The important convolution properties include width, area, differentiation, and integration properties.
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...