Related Experiment Video
Updated: Jun 3, 2026

Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
Comparison of Odiosoft-Rhino and rhinomanometry in evaluation of nasal patency
Rauf Tahamiler1, Rauf Tahamiller, Yalçin Alimoglu
1Department of Otorhinolaryngology, Istanbul University, Cerrahpasa Medical School, Istanbul, Turkey.
Objective:
To conduct a preliminary study testing the validity of the Odiosoft-Rhino (OR) in the evaluation of nasal patency in patients with nasal septal deviation and compare the results with visual analogue score (VAS) of nasal obstruction and rhinomanometry (RMM).
Methods:
OR and RMM were performed on 68 patients with nasal septal deviation and 61 healthy controls. VAS, nasal resistance values and nasal sound analysis were noted for the left and right nasal cavities.
Results:
There are statistically significant differences between VAS, RMM and nasal endoscopic findings between the patient and the control group. The OR results at expiratory and inspiratory 2000 - 4000 Hz and 4000 - 6000 Hz intervals for both nasal cavities show a statistically significant difference between the patient and control groups. Nasal endoscopic findings, RMM, OR results of the deviated sides in the 2000 - 4000 Hz interval correlate well with VAS.
Conclusions:
OR may be a practical test in assessment of nasal patency. OR at the 2000 - 4000 Hz interval shows a correlation with VAS. However, showing a correlation between a test and a variable is not the same as proving that it is a useful diagnostic test. Therefore, more studies with larger series are needed.
Related Concept Videos
Nose and Nasal Cavity
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...