Related Experiment Video
Updated: Jun 3, 2026

Scanning Transmission Electron Microscopy Tomography in Virology: 3D Imaging of High-pressure Frozen, Freeze-substituted Samples
Published on: August 6, 2025
Electron tomography reveals polyhedrin binding and existence of both empty and full cytoplasmic polyhedrosis virus
Justin Chen1, Jingchen Sun, Ivo Atanasov
1Department of Microbiology, Immunology and Molecular Genetics, University of California, Los Angeles, Los Angeles, CA 90095, USA.
Abstract:
Previous studies have described the structure of purified cytoplasmic polyhedrosis virus (CPV) and that of polyhedrin protein. However, how polyhedrin molecules embed CPV particles inside infectious polyhedra is not known. By using electron tomography, we show that CPV particles are occluded within the polyhedrin crystalline lattice with a random spatial distribution and interact with the polyhedrin protein through the A-spike rather than as previously thought through the B-spike. Furthermore, both full (with RNA) and empty (no RNA) capsids were found inside polyhedra, suggesting a spontaneous RNA encapsidating process for CPV assembly in vivo.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Viral Structure
Cryo-electron Microscopy
Poliomyelitis