Related Experiment Video
Updated: Jun 3, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality
Christoph Karlo1, Ralph Gnannt, Thomas Frauenfelder
1Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Abstract:
The purpose of this study is to assess the influence of different arm positioning techniques on thoracic and abdominal image quality and radiation dose of whole-body trauma CT (wbCT). One hundred and fifty polytrauma patients (104 male, mean age 47 ± 19) underwent wbCT with arms elevated above the head (group A, n=50), alongside the abdomen (group B, n=50), and on a pillow ventrally to the chest with both arms flexed (group C, n=50). Two blinded, independent observers measured image noise and rated image quality (scores 1-3) of the liver, aorta, spleen, spine, and lower lungs. Radiation dose parameters were noted, and the abdomens' anterior-posterior diameter and scan lengths were measured. Interreader agreements for image noise (r=0.86; p<0.001) and subjective image quality (k=0.71-0.84) were good. Noise was lower (p<0.05), image quality of the liver, aorta, spleen, and spine was higher, and radiation dose lower in group A than in groups B and C (p<0.001, each). Image quality of the spleen, liver, and aorta were higher in group C than in group B (p<0.05, each). No significant differences in scan length (p=0.61) were found among groups. Abdominal anterior-posterior diameter correlated significantly with noise (r=0.82; p<0.01) and dose (r=0.47; p<0.001). Estimated effective radiation doses were significantly (p<0.001) higher in groups B (21.2 mSv) and C (21.9 mSv) as compared to A (16.1 mSv). In wbCT for polytrauma patients, positioning of the arms above the head results in better image quality and lower radiation dose. Placing the flexed arms on a large pillow ventrally to the chest significantly improves image quality as compared to positioning alongside the abdomen.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Radiological Investigation I: X-ray and CT