"Speckled" ventricular septum in hypertrophic cardiomyopathy revisited after 30 years
Barry J Maron1, Jana Lindberg, Tammy S Haas
1Hypertrophic Cardiomyopathy Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA. hcm.maron@mhif.org
Insights
Echocardiographic "speckling" in hypertrophic cardiomyopathy does not reliably indicate myocardial fibrosis. Contrast-enhanced cardiovascular magnetic resonance imaging is the most accurate method for detecting left ventricular scarring in these patients.
Area of Science:
- Cardiology
- Medical Imaging
- Biomedical Engineering
Background:
- Hypertrophic cardiomyopathy (HCM) is a significant cardiovascular condition.
- Myocardial fibrosis is a key pathological feature in HCM, impacting cardiac function.
- Echocardiography, particularly "speckling" patterns, is often used to assess cardiac tissue characteristics.
Purpose of the Study:
- To investigate the relationship between echocardiographic "speckling" in the ventricular septum and myocardial fibrosis in HCM patients.
- To determine if echocardiographic "speckling" can accurately identify left ventricular scarring.
- To establish the most reliable imaging modality for diagnosing myocardial fibrosis in HCM.
Main Methods:
- Comparison of granular and reflective ultrasound patterns (speckling) in the ventricular septum.
- Assessment of myocardial fibrosis using contrast-enhanced cardiovascular magnetic resonance imaging (CE-CMR).
- Correlation analysis between echocardiographic findings and CE-CMR evidence of fibrosis.
Main Results:
- A highly inconsistent relationship was observed between echocardiographic "speckling" and myocardial fibrosis confirmed by CE-CMR.
- The "speckling" pattern in the ventricular septum does not accurately characterize left ventricular scarring in HCM.
- Echocardiographic "speckling" is likely an extraneous ultrasound signal pattern rather than indicative of fibrosis.
Conclusions:
- Echocardiographic "speckling" is an unreliable marker for myocardial fibrosis in hypertrophic cardiomyopathy.
- Contrast-enhanced cardiovascular magnetic resonance imaging (CE-CMR) is the gold standard for identifying myocardial fibrosis in HCM.
- Clinical decisions regarding myocardial fibrosis in HCM should rely on CE-CMR findings.
Abstract:
We found a highly inconsistent relation between the granular and reflective ultrasound ("speckling") pattern frequently observed in the ventricular septum of patients with hypertrophic cardiomyopathy and evidence of myocardial fibrosis by contrast-enhanced cardiovascular magnetic resonance imaging. Therefore, this distinctive echocardiographic appearance of the myocardium does not accurately characterize left ventricular scarring and is most likely explained as an extraneous ultrasound signal pattern. In conclusion, myocardial fibrosis in patients with hypertrophic cardiomyopathy is most reliably identified using contrast-enhanced cardiovascular magnetic resonance imaging.