Related Experiment Video
Updated: Jun 2, 2026

Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Intra- and inter-observer reliability in anthropometric measurements in children
S Stomfai1, W Ahrens, K Bammann
1Department of Paediatrics, Medical Faculty, University of Pecs, Hungary. sarolta.stomfai@kk.pte.hu
Introduction:
Studies such as IDEFICS (Identification and prevention of dietary- and lifestyle-induced health effects in children and infants) seek to compare data across several different countries. Therefore, it is important to confirm that body composition indices, which are subject to intra- and inter-individual variation, are measured using a standardised protocol that maximises their reliability and reduces error in analyses.
Objective:
To describe the standardisation and reliability of anthropometric measurements. Both intra- and inter-observer variability of skinfold thickness (triceps, subscapular, biceps, suprailiac) and circumference (neck, arm, waist, hip) measurements were investigated in five different countries.
Methods:
Central training for fieldwork personnel was carried out, followed by local training in each centre involving the whole survey staff. All technical devices and procedures were standardised. As part of the standardisation process, at least 20 children participated in the intra- and inter-observer reliability test in each centre. A total of 125 children 2-5 years of age and 164 children 6-9 years of age took part in this study, with a mean age of 5.4 (± 1.2) years.
Results:
The intra-observer technical error of measurement (TEM) was between 0.12 and 0.47 mm for skinfold thickness and between 0.09 and 1.24 cm for circumference measurements. Intra-observer reliability was 97.7% for skinfold thickness (triceps, subscapular, biceps, suprailiac) and 94.7% for circumferences (neck, arm, waist, hip). Inter-observer TEMs for skinfold thicknesses were between 0.13 and 0.97 mm and for circumferences between 0.18 and 1.01 cm. Inter-observer agreement as assessed by the coefficient of reliability for repeated measurements of skinfold thickness and circumferences was above 88% in all countries.
Conclusion:
In epidemiological surveys it is essential to standardise the methodology and train the participating staff in order to decrease measurement error. In the framework of the IDEFICS study, acceptable intra- and inter-observer agreement was achieved for all the measurements.
More Related Videos
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Reliability and Validity
One-Way ANOVA: Equal Sample Sizes
Different sample means can result in different values for the variance estimate: variance between samples. This is because the variance between samples is calculated as the product of the sample size and the variance between the...
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the strength of the linear...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Random and Systematic Errors

