Comparison of volume-controlled and pressure-controlled ventilation using a laryngeal mask airway during
Woo Jae Jeon1, Sang Yun Cho, Mi Rang Bang
1Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University Collge of Medicine, Guri, Korea.
Background:
Several publications have reported the successful, safe use of Laryngeal Mask Airway (LMA)-Classic devices in patients undergoing laparoscopic surgery. However, there have been no studies that have examined the application of volume-controlled ventilation (VCV) or pressure-controlled ventilation (PCV) using a LMA during gynecological laparoscopy. The aim of this study is to compare how the VCV and PCV modes and using a LMA affect the pulmonary mechanics, the gas exchange and the cardiovascular responses in patients who are undergoing gynecological laparoscopy.
Methods:
Sixty female patients were randomly allocated to one of two groups, (the VCV or PCV groups). In the VCV group, baseline ventilation of the lung was performed with volume-controlled ventilation and a tidal volume of 10 ml/kg ideal body weight (IBW). In the PCV group, baseline ventilation of the lung using pressure-controlled ventilation was initiated with a peak airway pressure that provided a tidal volume of 10 ml/kg IBW and an upper limit of 35 cmH(2)O. The end-tidal CO(2), the peak airway pressures (P(peak)), the compliance, the airway resistance and the arterial oxygen saturation were recorded at T1: 5 minutes after insertion of the laryngeal airway, and at T2 and T3: 5 and 15 minutes, respectively, after CO(2) insufflation.
Results:
The P(peak) at 5 minutes and 15 minutes after CO(2) insufflation were significantly increased compared to the baseline values in both groups. Also, at 5 minutes and 15 minutes after CO(2) insufflation, there were significant differences of the P(peak) between the two groups. The compliance decreased in both groups after creating the pneumopertoneim (P < 0.05).
Conclusions:
Our results demonstrate that PCV may be an effective method of ventilation during gynecological laparoscopy, and it ensures oxygenation while minimizing the increases of the peak airway pressure after CO(2) insufflation.
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques