Background And Objectives:
To determine whether warfarin prolongs the time to first mechanical-catheter failure.
Design, Setting, Participants, & Measurements:
This was a multicenter parallel-group randomized controlled trial with blinding of participants, trial staff, clinical staff, outcome assessors, and data analysts. Randomization was in a 1:1 ratio in blocks of four and was concealed by use of fax to a central pharmacy. Hemodialysis patients with newly-placed catheters received low-intensity monitored-dose warfarin, target international normalized ratio (INR) 1.5 to 1.9, or placebo, adjusted according to schedule of sham INR results. The primary outcome was time to first mechanical-catheter failure (inability to establish a circuit or blood flow less than 200 ml/min).
Results:
We randomized 174 patients: 87 to warfarin and 87 to placebo. Warfarin was associated with a hazard ratio (HR) of 0.90 (P=0.60; 95% confidence interval [CI], 0.57, 1.38) for time to first mechanical-catheter failure. Secondary analyses were: time to first guidewire exchange or catheter removal for mechanical failure (HR 0.78; 95% CI, 0.37, 1.6); time to catheter removal for mechanical failure (HR 0.67; 95% CI, 0.19, 2.37); and time to catheter removal for any cause (HR 0.89; 95% CI, 0.42, 1.81). Major bleeding occurred in 10 participants assigned to warfarin and seven on placebo (relative risk, 1.43; 95% CI, 0.57, 3.58; P=0.61).
Conclusions:
We found no evidence for efficacy of low-intensity, monitored-dose warfarin in preventing mechanical-catheter failure.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Venous Thrombosis III: Interprofessional Care
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Hemodialysis II: Procedure and Complications
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...