Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Thermal gratings and phase in high-order, transient-grating spectroscopy
1Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, USA.
Abstract:
Thermal gratings are a well known feature in one-dimensional (i.e., single excitation) transient-grating spectroscopy. This paper presents theory and experiments for thermal gratings in multiple dimensions (i.e., with many excitations). The theory of thermal gratings is extended to an arbitrary number of dimensions using an incoherent Hilbert-space formalism. Interference between Hilbert-space pathways makes it impossible for a thermal grating to propagate across multiple time intervals. The only surviving signal is a hybrid--a population grating between excitations and a thermal grating between the final excitation and the probe. This theory is tested on auramine O in methanol (1D) and in an ionic liquid (3-butyl-1-methylimidazolium hexafluorophosphate) (1D and 2D). In methanol, the ground-state recovery and thermal-grating signals are well separated in time; in the ionic liquid, they are not. Using the results of the theory, accurate subtraction of the thermal-grating signal is possible, extending the useful time range of the experiments. Both the comparison to the theory and the subtraction of the thermal-grating signal are dependent on accurate measurements of the time-dependent phase in these systems. Models are proposed to account for the time-dependent phase. Beer's law is generalized to multidimensional grating spectroscopy. This law provides conventions for consistently comparing the absolute phases and magnitudes between grating and nongrating experiments and between experiments of differing dimensionality.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
IR Spectrometers
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...