Vibration-response imaging versus quantitative perfusion scintigraphy in the selection of patients for lung-resection
Fatma Comce1, Zuleyha Bingol, Esen Kiyan
1Department of Pulmonary Diseases, Istanbul University, Istanbul, Turkey.
Background:
In patients being considered for lung-resection surgery, quantitative perfusion scintigraphy is used to predict postoperative lung function and guide the determination of lung-resection candidacy. Vibration-response imaging has been proposed as a noninvasive, radiation-free, and simpler method to predict postoperative lung function. We compared vibration-response imaging to quantitative perfusion scintigraphy for predicting postoperative FEV(1) and diffusing capacity of the lung for carbon monoxide (D(LCO)).
Methods:
We enrolled 35 candidates for lung resection. Twenty-five patients had preoperative FEV(1) and D(LCO) MEASUREMENTS:
Results:
The vibration-response-imaging measurements showed strong correlation with the quantitative-perfusion-scintigraphy measurements of predicted postoperative FEV(1)% (r = 0.87, P < .001), predicted postoperative FEV(1) (r = 0.90, P < .001), and predicted postoperative D(LCO)% (r = 0.90, P < .001). There was a correlation between predicted postoperative FEV(1) (% and L) measured via quantitative perfusion scintigraphy and the actual postoperative FEV(1) (% and L) (r = 0.47, P = .048, r = 0.73, P < .001). There was no difference between the vibration-response-imaging measurements and the actual postoperative measurements of predicted postoperative FEV(1) (% and L). There was a correlation between predicted postoperative FEV(1) (% and L) measured via vibration-response imaging and actual postoperative FEV(1) (% and L) (r = 0.52, P = .044, r = 0.79, P < .001). The mean differences between the predicted and actual postoperative FEV(1) values were 49 mL with vibration-response imaging, versus 230 mL with quantitative perfusion scintigraphy. Neither the vibration-response imaging nor the quantitative perfusion scintigraphy predicted postoperative D(LCO)% values agreed with the actual postoperative D(LCO)% values.
Conclusions:
Vibration-response imaging may be a good alternative to quantitative perfusion scintigraphy in evaluating lung-resection candidacy.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...