Joan Maria Raurich1, Gemma Rialp, Jordi Ibáñez
1Intensive Care Unit, Hospital Universitario Son Dureta, Palma de Malorca, Illes Balears, Spain. joan.raurich@ssib.es
Background:
The CO2 response test measures the hypercapnic drive response (which is defined as the ratio of the change in airway-occlusion pressure 0.1 s after the start of inspiratory flow [ΔP(0.1)] to the change in P(aCO2) [ΔP(aCO2)]), and the hypercapnic ventilatory response (which is defined as the ratio of the change in minute volume to ΔP(aCO2)).
Objective:
In mechanically ventilated patients ready for a spontaneous breathing trial, to investigate the relationship between CO2 response and the duration of weaning.
Methods:
We conducted the CO2 response test and measured maximum inspiratory pressure (P(Imax)) and maximum expiratory pressure (P(Emax)) in 102 non-consecutive ventilated patients. We categorized the patients as either prolonged weaning (weaning duration > 7 d) or non-prolonged weaning (≤ 7 d).
Results:
Twenty-seven patients had prolonged weaning. Between the prolonged and non-prolonged weaning groups we found differences in hypercapnic drive response (0.22 ± 0.16 cm H2O/mm Hg vs 0.47 ± 0.22 cm H2O/mm Hg, respectively, P < .001) and hypercapnic ventilatory response (0.25 ± 0.23 L/min/mm Hg vs 0.53 ± 0.33 L/min/mm Hg, respectively, P < .001). The optimal cutoff points to differentiate between prolonged and non-prolonged weaning were 0.19 cm H2O/mm Hg for hypercapnic drive response, and 0.15 L/min/mm Hg for hypercapnic ventilatory response. Assessed with the Cox proportional hazards model, both hypercapnic drive response and hypercapnic ventilatory response were independent variables associated with the duration of weaning. The hazard ratio of weaning success was 16.7 times higher if hypercapnic drive response was > 0.19 cm H2O/mm Hg, and 6.3 times higher if hypercapnic ventilatory response was > 0.15 L/min/mm Hg. Other variables (P(0.1), P(Imax), and P(Emax)) were not associated with the duration of the weaning.
Conclusions:
Decreased CO2 response, as measured by hypercapnic drive response and hypercapnic ventilatory response, are associated with prolonged weaning.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: