Using kV-kV and CBCT imaging to evaluate rectal cancer patient position when treated prone on a newly available belly
Gavin Cranmer-Sargison1, Vijayananda Kundapur, Deluan Tu
1Department of Medical Physics, Saskatchewan Cancer Agency, Canada. gavin.cranmer-sargison@saskcancer.ca
Abstract:
The goal of this work was to use daily kV-kV imaging and weekly cone-beam CT (CBCT) to evaluate rectal cancer patient position when treated on a new couch top belly board (BB). Quality assurance (QA) of the imaging system was conducted weekly to ensure proper performance. The positional uncertainty of the combined kV-kV image match and subsequent couch move was found to be no more than ± 1.0 mm. The average (1 SD) CBCT QA phantom match was anterior-posterior (AP) = -0.8 ± 0.2 mm, superior-inferior (SI) = 0.9 ± 0.2 mm, and left-right (LR) = -0.1 ± 0.1 mm. For treatment, a set of orthogonal kV-kV images were taken and a bony anatomy match performed online. Moves were made along each axis (AP, SI, and LR) and recorded for analysis. CBCT data were acquired once every 5 fractions for a total of 5 images per patient. The images were all taken after the couch move but before treatment. A 3-dimensional (3D-3D) bony anatomy auto-match was performed offline and the residual difference in position recorded for analysis. The average (± 1 SD) move required from skin marks, calculated over all 375 fractions (15 patients × 25 fractions/patient), were AP = -2.6 ± 3.7 mm, SI = -0.3 ± 4.9 mm, and LR = 1.8 ± 4.5 mm. The average residual difference in patient position calculated from the weekly CBCT data (75 total) were AP = -1.7 ± 0.4 mm, SI = 1.1 ± 0.6 mm, and LR = -0.5 ± 0.2 mm. These results show that the BB does provide simple patient positioning that is accurate to within ± 2.0 mm when using online orthogonal kV-kV image matching of the pelvic bony anatomy.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VI: Voiding Cystourethrography and Cystography