High-Density Lipoprotein-Specific Phospholipid Efflux Assay
Published on: September 30, 2025
Micellar electrokinetic chromatography profiles of human high-density lipoprotein phospholipids
Chin-Pong Chong1, Ting-Yu Lin, Chia-Liang Chang
1Department of Chemistry, National Changhua University of Education, Changhua, Taiwan.
Abstract:
A simple and fast micellar electrokinetic chromatography (MEKC) method was developed to investigate phospholipids isolated from human high-density lipoproteins (HDL). To optimize the MEKC conditions, several factors including bile salt concentration and organic modifier concentration in the separation buffer as well as temperature have been examined. The optimal separation buffer chosen was a mixture of 50 mM bile salts, 30% v/v 1-propanol and 10 mM sodium phosphate (pH 8.5). The applied voltage and temperature selected were 25 kV and 40°C, respectively. Meanwhile, high-salt stacking has been performed for sample pre-concentration to enhance peak sensitivity. Several factors including organic modifier concentration and salt concentration in the sample matrix as well as sample injection time have been optimized. The optimal sample buffer selected was a mixture of 100 mM NaCl and 20% 1-propanol, and the optimal sample injection time selected was 32 s under a pressure of 0.5 psi. Several phospholipid standards including lysophosphatidyl choline, phosphatidyl choline (PC), sphingomyelin, phosphatidyl ethanolamine, phosphatidyl inositol, phosphatidyl serine and phosphatidic acid have been studied using the optimal MEKC method. The MEKC profile of the mixed phospholipid standards showed good separation and reproducibility. The linear ranges for PC and sphingomyelin were 0.025-1.2 and 0.025-2.0 mg/mL, respectively. The concentration limits of detection of PC and sphingomyelin were 0.0156 and 0.0199 mg/mL, respectively. Using phosphatidic acid as an internal standard, precision and accuracy have been measured for PC and sphingomyelin. The intraday and interday quantitative analysis showed good results. The new MEKC method has been used to characterize native, in vitro oxidized and glycated human HDL phospholipids within 16 min. At absorbance 200 nm, two similar peaks were observed for native and oxidized HDL phospholipids, but three peaks were observed for glycated HDL phospholipids. Interestingly, at absorbance 234 nm, distinctively different MEKC profiles were observed for the three HDL phospholipids.
More Related Videos
07:33Lipid Vesicle-mediated Affinity Chromatography using Magnetic Activated Cell Sorting (LIMACS): a Novel Method to Analyze Protein-lipid Interaction
Published on: April 26, 2011
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Electrophoresis: Overview
There...
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...