Correct positioning for hip radiographs allows reliable measurement of hip displacement in cerebral palsy

Lucy Cliffe1, Don Sharkey, Grace Charlesworth

  • 1Nottingham Children's Hospital, Nottingham University Hospitals NHS Trust, Queens Medical Centre Campus, Nottingham, UK. lucy.cliffe@nuh.nhs.uk

Insights

Pelvic radiographs reliably measure hip displacement in children with cerebral palsy (CP) when performed correctly. Experienced radiologists and proper positioning ensure accurate migration percentage calculations for effective monitoring.

Area of Science:

  • Pediatric Orthopedics
  • Radiology
  • Cerebral Palsy Research

Background:

  • Cerebral palsy (CP) often involves hip displacement, a condition monitored using pelvic radiographs.
  • The migration percentage is a key radiographic measure, but its reliability has been questioned.
  • Accurate assessment is crucial for managing hip stability in children with CP.

Purpose of the Study:

  • To evaluate the reliability of radiographic assessment of hip displacement in children with CP.
  • To determine the impact of positioning and radiologist experience on measurement accuracy.
  • To validate the migration percentage as a reliable surveillance tool.

Main Methods:

  • 20 children (40 hips) with severe bilateral spastic CP (GMFCS IV-V) underwent two standard pelvic radiographs.
  • Migration percentage was measured twice by two independent, experienced radiologists 3 months apart.
  • Inter-observer and intra-observer reliability were assessed.

Main Results:

  • Mean migration percentage showed high consistency across measurements.
  • Intra-observer measurements (same observer, same time vs. 3 months apart) were 3.2% and 3.3%.
  • Inter-observer measurements (different observers, 3 months apart) were 3.7%.

Conclusions:

  • Reliable migration percentage measurements are achievable with correct positioning and experienced radiologists.
  • Radiographic assessment of hip displacement is a valid method for surveillance in pediatric CP.
  • Clinical decisions should account for a small, expected error margin in hip displacement measurements.