Automated Slide Scanning and Segmentation in Fluorescently-labeled Tissues Using a Widefield High-content Analysis System
Published on: May 3, 2018
Was the Scanner Calibration Slide used for its intended purpose?
BMC Bioinformatics
|April 23, 2011
Summary
This study challenges findings that Full Moon BioSystems calibration slides are inadequate for microarray scanner calibration. The original conclusions were flawed, and the recommendation against using these essential calibration slides is not supported by evidence.
Area of Science:
- Bioinformatics
- Microarray technology
- Biotechnology
Background:
- Microarray scanner calibration is crucial for accurate data generation.
- Photomultiplier tube (PMT) response is a key factor in scanner performance.
- The Scanner Calibration Slide from Full Moon BioSystems is used for microarray scanner calibration.
Discussion:
- The study critically evaluates the methodology and conclusions presented in BMC Bioinformatics 2010, 11:361 regarding the Scanner Calibration Slide.
- It argues that the mathematical model for PMT response proposed in the original article is flawed.
- The authors assert that the conclusions drawn about the inadequacy of Full Moon BioSystems calibration slides are not adequately supported by the data or methodology.
Key Insights:
- The original study's conclusions regarding the inadequacy of Full Moon BioSystems calibration slides are contested.
- The mathematical model for PMT response requires further validation and may not accurately reflect scanner performance.
- The recommendation against using the Scanner Calibration Slide is considered unsubstantiated.
Outlook:
- Further research is needed to rigorously assess microarray scanner calibration methods.
- Development of standardized and validated calibration protocols is essential for reliable microarray data.
- Accurate calibration is vital for the advancement of gene expression analysis and other microarray applications.
Related Concept Videos
Instrument Calibration
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
Glassware Calibration
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...